1.1 Product destination strong> p> 1.1.1 Measuring AC and DC high-potential series ITV-140R (hereinafter & ndash; & quot ; meters & quot;) designed for measuring direct and alternating sinusoidal current frequency of 50-60 Hz of up to 3 mA (ITV-140R-3), 9 mA (ITV-140R-9) and 30 mA (ITV-140R-30) in chains under the potential of up to 140 kV. p>
1.1.2 Feature of meters is the lack of a galvanic connection between the high potential and low potential indicator measuring circuits, which ensures complete safety of operation. p>
1.1.3 measuring instruments intended for use in the composition of the test plants indoors in a temperature range from + 5 ° C to + 40S, relative humidity to 90% at 25S and a pressure of from 630 to 800 mm Hg. v. p>
1.1.4 On site installation is not permitted shaking, vibrations, presence of vapor in the air corrosive fluids (acids, alkalis, etc.). p>
1.1.5 product may operated by one operator from among electricians persons having access to carry out works in systems with voltages higher than 1000. p>
1.1.6 Version 3 meters corresponds to a group of devices in accordance with GOST 22261. p>
1.2 The basic specifications h3>
1.2.1 The working range of the measured currents is shown in table 1. p>
table 1 strong> p> | meter Design p> td> | ITV-140R-3 p> td> | ITV-140R-9 < / p> td> | ITV-140R-30 p> td> tr> |
| The operating range of the measured currents, mA p> < / td> | 0,010 & ndash; 3,000 p> td> | 0,030 & ndash; 9,000 p> td> | 0,10 & ndash; 30,00 p> td> tr> table> NOTE: & ndash; meters measure the mean (srednevypryamlennoe) DC value and RMS value of the AC 50-60 Hz p> 1.2.2 Bandwidth ac Hz -. 0-1000 p> 1.2. 3 Input resistance BW given in table 2. p> table 2 strong> p> | Design meter p> td> | ITV-140R-3 p> td> | ITV-140R-9 p> td> | ITV-140R-30 p> td> tr> | | impedance, ohms p> td> | 232 p> < /td> | 78 | 23 | 1.2.4 limit of absolute error measuring the operating range p> measured currents and temperatures is determined by the formula: p> = 0,01 ∙ ix + 5 e.m.r. (1) p> where, ix & ndash; value of measured current in mA; e.m.r. & Ndash; . Unit LSB p> 1.2.5 Resolution reference mA & ndash; 0,001 p> 1.2.6 Performance & ndash; Two measurements per second p> 1.2.7 radio frequency range, MHz, 845-945 p> 1.2.8 number of frequency channels 16 p> 1.2.9 Transmitter power, 1 mW p> 1.2.10 radio range (open space) m - 5-10 p> 1.2.11 meter withstands overload current single pulse duration of 10 ms and an amplitude of not more than 150 A. p> 1.2.12 Nutrition BV and MI produced from embedded Ni-MH AA size battery voltage of 1.2 V and a capacity of 2.1 A ∙ h. p> 1.2.13 voltage power & ndash; 5B, the duration of continuous operation without recharging & ndash; at least 8 h p> 1.2.14 dimensions / mass: p> & bull;. ITV block high-potential-140R-BV - 170h100 mm diameter / 1 kg; p> & bull; module indicator ITV3-MI - 95h190h40mm / 0.5 kg p> 1.2.15 Product life & ndash; 10 years p>
Terms and Conditions Shipping and payment Warranties & Returns Contacts
Documentation for download of the device not available
|