"CELS" - center of measuring systems. ph.: (095)191-68-69, (098)191-68-69 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

Wattmeter D5067

Specify the price
Availability: under the order   Condition: new




wattmeter & nbsp; D5067 & nbsp; for use in temperate climates in closed dry heated premises at ambient temperature from 5 to 40 & deg; C and a relative humidity of 90% at 25 & deg; C

< strong> basic specifications

& nbsp;

& nbsp; & nbsp; & nbsp; & nbsp; class precision wattmeters 0.5 according to GOST 8476-78. Basic parameters wattmeter & nbsp; D5067ukazany in. Table 1. Rated power factor wattmeter 1. wattmeter current branch circuit (3 & plusmn; 0,06) mA. Normal frequency region wattmeters 45 to 65 Hz, the operating frequency region - over 65 to 500 Hz

& nbsp;. & Nbsp; & nbsp; & nbsp; Maximum permissible error wattmeter & nbsp; D5067 & nbsp; in the normal range of frequencies and at constant stream is & plusmn; 0,5% of the final value of the measuring range. The limit of tolerable additional error wattmeter & nbsp; D5067 induced voltage deviation of & plusmn; 20% of its nominal value at a constant value of the measured power is equal to & plusmn; 0.5% of the final value of the measuring range

& nbsp;. & Nbsp; & nbsp ; & nbsp; Maximum permissible additional error wattmeter & nbsp; D5067 caused frequency deviation from the upper limit of the normal range of frequencies to any frequency value in the operating frequency range is & plusmn; 0,5% of the final value of the measuring range. The limit of tolerable additional error wattmeter & nbsp; D5067, caused by changes in ambient temperature from normal (20 & plusmn; 2) & nbsp; & deg; C to any temperature within the operating range, is & plusmn; 0.5% of the final value of measuring range per 10 & deg; As the temperature changes

& nbsp;. & nbsp; & nbsp; & nbsp; wattmeter Response time does not exceed 4 sec. at a temperature (20 & plusmn; 2) & deg; C. Dimensions wattmeter (140 & plusmn; 1,25) x (195 & plusmn; 1,45) x (92 & plusmn; 2,7) mm. wattmeters mass does not exceed 1.5 kg.

Table №1

Symbol wattmeter Nominal < br>


nal-



ny & nbsp;



current
The final value of the power measurement range for rated voltages power The need



trolled in the post



dovatel-



Noah & nbsp;



circuit, V & middot; A
30B 75V 100V 150V 300V 450V 600V
D5067,

D5067-04.1
1A - - 100W 150W - - - < td> 0,035
5A - - 500W 750W - - - 0,135

Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts

Documentation for download of the device not available

To order, fill out the form


cels.com.ua

Callback order form

cels.com.ua