Wattmeter D50563

Specify the price
Availability: under the order   Condition: new




wattmeter & nbsp; D50563 & nbsp; for use in temperate climates in closed dry heated premises at an ambient temperature of 10 to 35 & deg; C and a relative humidity of 80% at 25 & deg; C

& nbsp; Technical

  • & nbsp; & nbsp; & nbsp; & nbsp; D50563 & nbsp wattmeters; accuracy class 0.1 GOST 8476-78 immediately after setting the operating mode and during any uptime
  • & nbsp;. & nbsp; & nbsp; & nbsp; The main instrument settings & nbsp; D50563 & nbsp; are listed in the table. Rated power factor wattmeter 1.0. Rated current 5mA wattmeter parallel circuit. Normal frequency region wattmeters 45 to 65 Hz, the working area of ​​65 to 500 Hz
  • & nbsp;. & Nbsp; & nbsp; & nbsp; Maximum permissible additional error devices & nbsp; D50563 caused frequency deviation from an upper normal region to the boundary any value in a working frequency region equal to & plusmn; 0.1% of the final value of the measurement range,
  • & nbsp; & nbsp; & nbsp; & nbsp; Maximum permissible additional error wattmeter & nbsp; D50563, caused by the change of voltage on & plusmn; 20% of its nominal value at a constant value of the measured power is equal to & plusmn; 0,1% of the final value izmereniy.Vremya range establishing readings no more than 4
  • & nbsp;. & nbsp; & nbsp; & nbsp; Maximum permissible additional error devices & nbsp; D50563, caused by changes in ambient temperature by (20 & plusmn; 2) & deg; C to any temperature within the operating range for every 10 & deg; C does not exceed & plusmn; 0.1% of the final value of the measuring range
  • & nbsp;. & nbsp; & nbsp; & nbsp; Tensile tolerable additional error devices & nbsp; D50563, caused by the influence of the external homogeneous DC or AC (frequency within the normal field frequency) magnetic field with induction 0.5 mT, is & plusmn; 0,5% of the final value measurable range rhenium
  • & nbsp;. & nbsp; & nbsp; & nbsp; Power circuit luminous pointer lighting devices & nbsp; D50563 & nbsp; produced by the AC voltage (220 & plusmn; 22) & nbsp; & nbsp; frequency of 50-60Hz transformer, can be combined with the device, either directly from the source of direct or alternating voltage 4B
  • & nbsp; & nbsp; & nbsp; & nbsp; Dimensions device & nbsp; wattmeter D50563:. 205h290h135 mm. Weight of the device is not more than 4.5 kg. Overall size of the transformer housing: 65x85x45 mm. transformer Weight not more than 0.5 kg. < td> 0.5A
    wattmeter D50563
    Rated current, A The final value of the measurement range, W, for nominal voltages Parameters series circuits
    resistance, Ohm the par induction



    tiv-

    Nost, mH
    30B 75V 150V 300V 450V 600V
    15 37.5 75 150 225 300 0.28 0.2
    1A 30 75 150 300 450 600 0,075 0,05

    Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts