wattmeter & nbsp; D50562 & nbsp; is & nbsp; for accurate power measurement in the AC and DC circuits

Specifications

  • & nbsp;. & Nbsp; & nbsp; & nbsp; wattmeters D50562 & nbsp; accuracy class 0.1 GOST 8476-78 immediately after setting the operating mode and during any time of continuous operation
  • & nbsp;. & nbsp; & nbsp; & nbsp; Basic instrument settings & nbsp; D50562 & nbsp; indicated in the table. Rated power factor wattmeter 1.0. Rated current 5mA wattmeter parallel circuit. Normal frequency region wattmeters 45 to 65 Hz, the working area of ​​65 to 500 Hz
  • & nbsp;. & Nbsp; & nbsp; & nbsp; Maximum permissible additional error devices & nbsp; D50562 caused frequency deviation from an upper normal region to the boundary any value in a working frequency region equal to & plusmn; 0.1% of the final value of the measurement range,
  • & nbsp; & nbsp; & nbsp; & nbsp; Maximum permissible additional error wattmeter & nbsp; D50562, caused by the change of voltage on & plusmn; 20% of its nominal value at a constant value of the measured power is equal to & plusmn; 0,1% of the final value of the measurement range & nbsp;. Response time unit no more than 4
  • & nbsp;. & nbsp; & nbsp; & nbsp; Maximum permissible additional error devices & nbsp; D50562, caused by changes in ambient temperature air from (20 & plusmn; 2) & deg; C to any temperature within the operating range for every 10 & deg; C does not exceed & plusmn; 0.1% of the final value of the measuring range
  • & nbsp;. & nbsp; & nbsp; & nbsp ; Maximum permissible additional error devices & nbsp; D50562, caused by the influence of the external homogeneous DC or AC (frequency within the normal field frequency) magnetic field with induction 0.5 mT, is & plusmn; 0,5% of the final value range and measuring
  • & nbsp;. & nbsp; & nbsp; & nbsp; Power circuit luminous pointer lighting devices & nbsp; D50562 & nbsp; produced by the AC voltage (220 & plusmn; 22) & nbsp; & nbsp; frequency of 50-60Hz transformer, can be combined with the device, either directly from the source of direct or alternating voltage 4B
  • & nbsp; & nbsp; & nbsp; & nbsp; Dimensions device & nbsp; wattmeter D50562:. 205h290h135 mm. Weight of the device is not more than 4.5 kg. Overall size of the transformer housing: 65x85x45 mm. transformer Weight not more than 0.5 kg. < td> 2.5A
    wattmeter D50562
    Rated current, A The final value of the measurement range, W, for nominal voltages Parameters series circuits
    resistance, Ohm the par induction



    tiv-

    Nost, mH
    30B 75V 150V 300V 450V 600V
    75 187,5 375 750 1125 1500 0.022 0.008
    5A 150 375 750 1500 2250 3000 0,006 0,002