"CELS" - center of measuring systems. ph.: (095)191-68-69, (098)191-68-69 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

Wattmeter D50163

Specify the price
Availability: under the order   Condition: new




wattmeter & nbsp; D50163 & nbsp; is & nbsp; to measure current, voltage and power in circuits & nbsp; . AC and DC

Specifications

  • & nbsp; & nbsp; & nbsp; D50163 power meter corresponds to the class of accuracy of 0.2 according to GOST 8476-78 immediately after turning on and within any time continuous operation & nbsp;.
  • & nbsp; & nbsp; & nbsp; Rated power factor wattmeter D50163 & ndash; 1.0. Rated current parallel circuit wattmeter 5mA & nbsp;.
  • & nbsp; & nbsp; & nbsp; Normal wattmeter D50163 frequency region of 45 to 500 Hz, the operating frequency range & ndash; 500 to 1000 Hz, & nbsp;.
  • & nbsp; & nbsp; & nbsp; The limit of tolerable additional error wattmeter D50163 induced voltage deviation of & plusmn; 20% of the nominal value measured at constant power equal to the limit of tolerable basic error & nbsp;.
  • & nbsp; & nbsp; & nbsp; Changing Power meter readings D50163 caused by change in frequency from the upper limit of normal field to any value in the working frequency range does not exceed & plusmn; 0.2% of the final value of the measuring range
  • & nbsp;. & Nbsp; & nbsp; Limit device tolerable additional error wattmeter D50163 caused by the influence of the external homogeneous DC or AC (frequency within the normal range of frequencies, but no more than 1 kHz) of the magnetic field with magnetic induction of 0.2 mT, does not exceed & plusmn; 0.2% of the final value of the measurement range & nbsp;.
  • & nbsp; & nbsp; & nbsp; settling time readings no more than 4s. Power supply lighting circuit wattmeter D50163 produced by AC voltage (220 & plusmn; 22) V 50 & ndash; 60 Hz via a step-down transformer (supplied with devices) or directly from an AC or DC voltage 4B
  • & nbsp;. & Nbsp; & nbsp; Overall dimensions wattmeter D50163 no more 205h290h135 mm unit weight of not more than 4.5 kg. Dimensions of the transformer housing is not more 65h85h45 mm, the transformer weight no more than 0.5 kg.
    wattmeter D50163
    Rated current, A The final value of the measuring range W, the rated voltage for Nomina-





    flax active





    Noah resistance





    Lenie, Om
    Nomina-





    Ordering inductive-ness, mH
    30B 75V 150V 300V 450V 600V < / td>
    0,5 15W 37,5Vt 75W 150W 225Vt 300W 0.1 0.087
    1 < / td> 30W 75W 150W 300W 450W 600W 0,028 0,022

    Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts

    Documentation for download of the device not available

    To order, fill out the form


    cels.com.ua

    Callback order form

    cels.com.ua