"CELS" - center of measuring systems. ph.: (095)191-68-69, (098)191-68-69 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

Wattmeter D50162

Specify the price
Availability: under the order   Condition: new




wattmeter & nbsp; D50162 & nbsp; are designed to measure current, voltage and power in circuits & nbsp; DC and AC & nbsp;.

Specifications

  • & nbsp; & nbsp; & nbsp; D50162 power meter corresponds to the class of accuracy of 0.2 according to GOST 8476-78 immediately after turning on and within any time continuous operation & nbsp;.
  • & nbsp; & nbsp; & nbsp; Rated power factor wattmeter D50162 & ndash; 1.0. Rated current parallel circuit wattmeter 5 mA. Normal wattmeter D50162 frequency region of 45 to 500 Hz, the operating frequency range & ndash; 500 to 1000 Hz, & nbsp;.
  • & nbsp; & nbsp; & nbsp; The limit of tolerable additional error wattmeter D50162 induced voltage deviation of & plusmn; 20% of the nominal value measured at constant power equal to the limit of tolerable basic error & nbsp;.
  • & nbsp; & nbsp; & nbsp; Changing Power meter readings D50162 caused by change in frequency from the upper limit of normal field to any value in the working frequency range does not exceed & plusmn; 0.2% of the final value of the measuring range
  • & nbsp;. & Nbsp; & nbsp; Limit device tolerable additional error wattmeter D50162 caused by the influence of the external homogeneous DC or AC (frequency within the normal range of frequencies, but no more than 1 kHz) of the magnetic field with magnetic induction of 0.2 mT, does not exceed & plusmn; 0.2% of the final value of the measurement range & nbsp;.
  • & nbsp; & nbsp; & nbsp; settling time readings no more than 4s. Power supply circuit device wattmeter D50162 illumination produced by the AC voltage (220 & plusmn; 22) V 50 & ndash; 60 Hz via a step-down transformer (supplied with devices) or directly from an AC or DC voltage 4B
  • & nbsp;. & Nbsp; & nbsp; Overall dimensions wattmeter D50162 no more 205h290h135 mm unit weight of not more than 4.5 kg. Dimensions of the transformer housing is not more 65h85h45 mm, the transformer weight no more than 0.5 kg.
    wattmeter D50162
    Nomina-



    flax current, A
    The final value of the measuring range W, the rated voltage for Nomina-



    flax active resistance



    Lenie, Om
    Nomina-
    < br />

    Ordering inductive-ness, mH
    30B 75V 150V 300V 450V 600V
    2,5 75W 187,5Vt 375Vt 750W 1125Vt 1500W 0,022 0,008
    5 150W 375Vt 750W 1500W 2250Vt 3000W 0,006 0,002

    Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts

    Documentation for download of the device not available

    To order, fill out the form


    cels.com.ua

    Callback order form

    cels.com.ua