Electrical installation & nbsp; TOS-5M & nbsp; is intended to measure the dielectric strength at a test AC voltage up to 6 kV

The device for measuring the electrical strength test constant or variable voltage

Features:

  • test voltage to 6kV;
  • a current measuring range leak;
  • digital scale;
  • automatic and manual modes;
  • automatic and manual modes;
  • setting threshold leakage current;
  • setting voltage change in the law for the automatic mode;
  • storing and viewing the results of the last test;
  • stored in non-volatile memory of the test results;
  • ability to connect an external light or sound alarm and remote start button



    specifications:

    Output Voltage Reference Range: & nbsp; & nbsp;
    permanent kV ( only for option I) & nbsp; 0,2-6
    AC, kV & nbsp; 0,2-6
    Discrete measurement of the output voltage, kV & nbsp; 0,01
    The DC voltage (for version V): & nbsp; & nbsp;
    pulsation idle% of the output voltage, not more than & nbsp; 5
    Variable voltage: & nbsp; & nbsp;
    waveform & nbsp; Sine
    frequency, Hz & nbsp; 50 & plusmn; 1 < tr> THD, max,% & nbsp; 10
    Deviation reference output voltage with instability input voltage of 2% in the range 198 & nbsp; & ndash; 242B: & nbsp; & nbsp;
    constant th (only option Y) 0,2kV & nbsp; & ndash; 6kV, max,% & nbsp; 3
    AC 0,2kV & nbsp; & ndash; 6kV, max,% & nbsp; 3
    Leakage current measurement mA & nbsp ; 0,1-100
    Deviation leakage current when the input voltage instability 2% in the range 198 & nbsp; & ndash; 242B,% & nbsp; 5
    Setting range threshold voltage, kV & nbsp; 0,2-6
    setting range threshold leakage current, mA & nbsp; 1-99
    Resolution set a threshold voltage, kV & nbsp; 0,1
    Resolution setting threshold leakage current, mA & nbsp; 1
    duration range slew the output voltage from 0 to the set threshold value in automatic mode, sec & nbsp; 2-100
    range retaining duration output voltage at the prescribed threshold value in automatic mode, sec & nbsp; 2-240
    variation range of the output voltage decay duration from the threshold value to 0 in the automatic mode, sec & nbsp; 2-100
    and discreteness Changes duration, sec & nbsp; 1
    Maximum under test container in an automatic mode or smooth increase of the output voltage in the manual mode at a voltage (for version V): & nbsp; & nbsp;
    1 kV, no more uF & nbsp; 20
    3 kV and no more, uF & nbsp; < td> 10
    6 kV not more uF & nbsp; 5 < tr> The time required for the discharge of the test capacitors after the test, not more, sec (only option I) & nbsp; 30
    voltage to an external indicator, V & nbsp; 12
    current for the external indicator is not more mA & nbsp; 200
    The maximum output power is not less kVA

    & nbsp;