The device is a high voltage AV 50 / 70-2
|
1. PURPOSE h3>
1.1. Apparatus high voltage AV 50 / 70-4 (hereinafter & ndash; & laquo; apparatus & raquo;) for: p>
- insulation test safeners (rubber boots, gloves, power tools and the like) variables high voltage power frequency adjustable within 0 - 50kV li>
- testing the insulation of power cables and solid dielectrics rectified electrical voltage to 60 kV, as well as for testing of solid dielectrics sinusoidal electric voltage frequency of 50 Hz
- determine the breakdown voltage of liquid dielectrics 50 Gts.do50kV voltage frequency. (GOST 6581-75) li>
- Measurement of leakage current test objects (safeners, fuses, etc.) Li> ul>
& nbsp; p>
1.2. The apparatus is designed for operation under a canopy or smokers at operating air temperatures from minus 10 & deg; C to plus 40 & deg; C, 80% relative humidity at a temperature of 20 & deg; C and atmospheric pressure 84,0 & ndash; 106.7 kPa (630 & ndash; 800 mm Hg...) P>
1.3.. The apparatus can be used in two ways: p>
- stationary, li>
- laptop li> ul>
1.4.. To use this machine requires two operators who have permits to work on electrical installations with voltage over 1000 V p>
& nbsp;. P>
2. SPECIFICATIONS h3>
2.1. Power & ndash; single-phase AC mains voltage of 220 & plusmn; 20 V, frequency 50 & plusmn; 2Hz p>
2.2. Power consumption, not more, VA 2000 p>
2.3. Number of high-voltage sources - 4 p>
2.4. Parameters of the sources listed in Table 2.1 p>
Table 2.1 strong> p>
Option p> td>
source Type p> td> tr>
BVI-50 p> td>
BVI- 20 p> td>
BVI-1 p> td> tr>
Most AC output voltage, kV p> < / td>
50 p> td>
20 p> td>
1 p> td> tr>
The highest DC output voltage, kV p> td>
70 p> td>
- p > td>
- p> td> tr>
The highest output current mA p>
& nbsp; p > td>
35 p> td>
35 p> td>
50 p> td> tr>
Overall dimensions p> td>
270h295h660 p> td>
270h295h660 p > td>
225h160h195 p> td> tr>
Weight kg p> td>
35 p> td>
35 p> td>
3 p> td> tr> table>
2.5. Test the bath parameters: p>
- The number of test electrodes & ndash; 4; li>
- dimensions (stand), mm 670h470h1120 li>
- dry weight, kg, not more than 10 li> ul>
2.6. The parameters embedded kilovoltmeter: p>
- limits measuring AC voltage, kV, - 1, 20, 50; li>
- reduced relative measurement error,%, no more than - 3 li > ul>
2.7. Embedded current meter Parameters: p>
- Measurement limit (AC and DC), mA, 25; li>
- reduced relative measurement error,%, no more than 3 li> < /ul>
2.8. a high-potential power meter parameters ITVR-4: p>
- measurement limit (AC and DC), mA, 10; li>
- reduced relative measurement error,%, no more than 3 li> ul>
2.9. The area occupied by the apparatus (recommended), m2, 4 p>
2.10. equipment weight, kg, no more 100 p>
2.11. Life of the equipment device & ndash; 10 years p>