1. PRODUCT DESIGNATION

Unit test AID-70M-0.6 (hereinafter in the text & ndash; apparatus) for testing the insulation of power cables and solid dielectrics rectified electrical voltage, as well as for testing of solid dielectrics sinusoidal electric voltage frequency of 50 Hz .

The device is designed for operation under a canopy or smokers at operating air temperatures from minus 10 & deg; C to plus 40 & deg; C, 80% relative humidity at a temperature of 20 & deg; C and atmospheric pressure 84,0 & ndash; 106.7 kPa (630 & ndash; 800 mm Hg...)

& nbsp;.

2. SPECIFICATIONS

2.1. Voltage supply single-phase

AC, B, 220 & plusmn; 11

2.2. Parameters apparatus for rectified voltage in continuous operation at nominal line voltage:

  • maximum working voltage, kV, 70;
  • maximum operating current, mA, 35

    2.3. Parameters of the apparatus with AC voltage in continuous operation at nominal line voltage:

    • maximum working voltage (rms) kV, 50
    • greatest operating current (rms) mA, 20

      2.4. Parameters of the apparatus with AC voltage in intermittent mode with a duty cycle (MF) 17%, and cycle time 6 min. at nominal line voltage:

      • maximum working voltage (rms) kV, 50
      • greatest operating current (rms) mA, 45

        2.5. Power consumption, kVA, no more than 3

        2.6.

        The above measurement of the output voltage and the error current,%, at more than 3

        2.7. Weight, not more than:

To order, fill out the form


cels.com.ua