LLC "CELS" - center of measuring systems. ph.: (098)296-57-76 (066)169-95-75 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

multimeter V7-61

Price: up from 30400,00 uah.*
Availability: under the order   Condition: new




*- the specified cost is not a public offer, it is provided for informational purposes as the average price of this type of equipment, both new (in the most popular configurations) and warehouse storage.

Multimeter V7-61 & nbsp; designed for measuring electrical quantities: voltage and the DC and AC currents, and the DC resistance and testing pn junctions

is used when setting and repair elektroradiotehnicheskih devices in laboratory and field. . circumstances

Small size, self-powered, a wide range of measured voltages frequencies and full protection against overloads

Main specifications:

& nbsp; .

Parameter

The range of measured values ​​

measurement limits

Maximum permissible error,%

Note

1

2

3

4 < p> 5

The DC voltage U -

10-4 & ndash; 103

200mV

& nbsp;

- < / p>

2; 20; 200

& nbsp;

1000 < td>

& nbsp;

AC voltage U ~ 20-40 Hz frequency

< p> 10-3 & ndash; 750

2; 20; 200

& nbsp;

Kg? 2,5%

750

& nbsp;

Kg? 4%

U ~ frequency of 40 Hz-1kHz

10-3 & ndash; 750

2; 20; 200

& nbsp;

Kg? 1%

750

& nbsp; < td>

Kg? 2,5%

U ~ 1-20kGts frequency

10-3 & ndash; 200

2; 20; 200

& nbsp;

Kg? 2%

U ~ frequency 20-100kGts

10-3 & ndash; 20 In

2; 20 In

& nbsp;

Kg? 6%

DC resistance R

10-3 & ndash; 2 & bull; 103 k

200 ohm

2; 20; 200 kOhm

2 Mohm

& nbsp;

-

DC power of I -

10-2 & ndash; 104 mA

20; 200 mA

& nbsp;

-

10A

& nbsp;

The strength of the AC I ~ frequency 20- 40Hz

10-2 & ndash; 2 & bull; 104 mA

20; 200 mA

& nbsp;

Kg? 2,5%

10 A

& nbsp;

Kg? 4%

I ~ frequency of 40 Hz-1 kHz

10-2 & ndash; 2 & bull; 104 mA

20; 200 mA

& nbsp;

Kg? 1,5%

10A

& nbsp;

Kg? 2,5%

I ~ frequency 1-10 kHz

10-2 & ndash ; 200 mA

20; 200 mA

& nbsp;

Kg? 2%

& nbsp;

Note: & nbsp; Ux, Ix, Rx readings < br>
Un, In, Rp measurement limits of voltage, current, resistance, respectively;

harmonic coefficient Cg

operating conditions: .

  • ambient temperature from & ndash; 10 + 55 & deg; C;
  • relative humidity to 100% at a temperature up to 35 & deg; C;
  • voltage 7-10V power from an autonomous source (battery type & quot; sheet & quot ;, & quot; Crohn-VTS & quot;);
  • device resistant to a reduced atmospheric pressure to 170 mm Hg;. < li> device remains operational after the fall in the case with a height of 1 m on a flat surface;
  • device remains operational after immersion in water at a depth of 1 m

    The input capacitance of device during measurement. AC voltage not more than 50pF.

    The voltage drop across the input unit nests in the measurement of DC and AC power ennogo 20mA currents within 10A is less than 0,35V at 200mA & ndash limit; does not exceed 3.0V.

    The maximum value of the voltage drop on the measured resistance is less than 3.0V.

    The unit has an overload indication of battery discharge.

    The device is protected . all the inputs from the effects of accelerations

    measurement time does not exceed:

    • 2c when measuring voltage and constant current; < li> 5c when measuring voltage power AC and DC resistance.

      power of current consumption from the battery, not more than 2 mA.

      unit dimensions less than 35 , 5h90h191 mm.

      unit weight of not more than 0,65kg.

      MTBF least 55000ch.