voltmeter universal DNV

Specify the price
Availability: under the order   Condition: new




The voltmeter universal & nbsp; DNV & nbsp; - high-voltage divider used to expand the DC voltage measurement limits the input impedance (10 & plusmn; 0,05) Mohm

& nbsp; & nbsp; & nbsp; & nbsp; DNV divider has a range of DC input voltages - 0-40kV. For high voltage products divider DNV voltage dividing ratios of 1: 1000 and 1: 2000, 1: 5000. Thus DNV error is 0.5% or 0,6%

& nbsp;. & Nbsp; & nbsp; & nbsp; Dividers DNV output voltage are input DC resistance & nbsp; (500 & plusmn; 25) ohms and the output impedance of the constant current (0,526 & plusmn; 0,026) Mohm

& nbsp;. & nbsp; & nbsp; & nbsp; Dividers high-voltage DNV & nbsp; made sizes 515 & times; 80 & times; 80 mm and a weight of 1 kg



& nbsp;. & nbsp; & nbsp; & nbsp; specifications DNV



& nbsp; & nbsp; & nbsp; & nbsp; Dividers DNV & nbsp; are supplied with a voltmeter V7-40. They provide a measurement of the DC voltage from 1 kV to 30 kV, and the voltmeter readings correspond to:

& nbsp; & nbsp; & nbsp; & nbsp; - 0,001U (DNV) for measuring DC voltmeter voltage DNV;

& nbsp; & nbsp; & nbsp; & nbsp; - 0,0005U (DNV) for measuring DC voltmeter voltage DNV and shunt K2;

< strong> & nbsp; & nbsp; & nbsp; & nbsp; - 0,0002U (DNV) for measuring DC voltmeter voltage DNV and shunt R3;

& nbsp; & nbsp; & nbsp; & nbsp; where U (DNV) - the value of the measured voltage at the input of the high-voltage divider DNV voltage



& nbsp; & nbsp; & nbsp; & nbsp; divider DNV & nbsp; has the following limits of allowable values ​​of the basic error in measuring the DC voltage equal to:

& nbsp; & nbsp; & nbsp; & nbsp; - voltmeter DNV + / - (0,4 + 0,04 (Uk / U - 1);

& nbsp; & nbsp; & nbsp; & nbsp; - voltmeter DNV and shunt K2 : +/- (0,4 + 0,04 (Uk / Ush1 & nbsp; - 1);

& nbsp; & nbsp; & nbsp; & nbsp; - voltmeter DNV and shunt K3 : +/- (0,4 + 0,04 (Uk / Ush2 & nbsp; - 1);

& nbsp; & nbsp; & nbsp; & nbsp; where Uk - finite value set limit measuring voltmeter (200mV, 2B; 20B; 200B), U = 0,001 U (DNV) Ush1 = 0,0005 U (DNV) Ush2 = 0,0002 U (DNV), U (DNV) - the value of the measured voltage at the input of the high-voltage divider DNV
<. br /> & nbsp;

& nbsp; & nbsp; & nbsp; & nbsp; limits values ​​additional error voltmeter V7-40 (V7-40 / 1) to DNV, but also with DNV and shunts K2 and K3 when measuring DC voltage equal to half the basic error of the temperature change on every 10ᵒS within the operating temperature range & nbsp.; & Nbsp;