"CELS" - center of measuring systems. ph.: (095)191-68-69, (098)191-68-69 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

Production / Radiomeasuring equipment / Power supplies / DC voltage (current) source B5-48

DC voltage (current) source B5-48

Specify the price
Availability: under the order   Condition: new




constant voltage source (AC) & nbsp; B5-48 & nbsp;. For power radio devices with stabilized voltage and current in the laboratory and workshop conditions

The magnitude of the output voltage and current can be adjusted manually or remotely by electrical signals to code 8-4-2-1.

It is possible to work B5-48 source with an isolated output, and by grounding terminals of either polarity.

The output voltage is guaranteed not only the terminals , but also directly at the load, which is achieved through the use of four-wire system connecting the load to a source of

& nbsp;

Main technical characteristics of the device B5-48:.



The value of output voltage: 0,1-49,9 In

The load current:. 0,01-1,99 A .

Fitting Readability: & nbsp;

voltage, mV 100;

current in mA: 10

Volatility,%:
when changing the voltage on & plusmn; 10%: & nbsp;

on conjugation: 0,01;

current: 0,05;

when the load changes from 0 to 0.9 Rmax:

voltage: 0.05;

current: 0,1

Fitting error:

voltage:. & plusmn; (0,5% Uust Vmax + 0.1%) in < br>
current: & plusmn; (Iset 1% + 0.2% Imax) A

Operation mode setup time when programming: 100ms

consumption:.. 400 A *



Weight. 9 kg

Dimensions:.. 236h326h133 mm

Replaces: B5-8

Possible replacement: & nbsp; ... B5-78 B5-78 / 7

Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts