Production / Electricalmeasuring equipment / Bridges and potentiometers / Bridge P333
Bridge P333
|
R 333 bridge DC measurement range: from 1 to 99,990 ohms
- resistivity measurements on a single bridge circuit;
- fault location of the cable through the loop Varley;
- fault location of the cable by Murray loop;
- The measurements were performed asymmetry;
- use as stores resistances. Li> ul>
measuring bridge DC P333 is designed to measure the electric resistance of cable fault location, measurements of the asymmetry of wires used as shop resistances. p>
Main specifications P333 device: h3>measurement range P333 strong> td> of 1 to 99990 ohms accuracy class 0,5
from 1 x 10 -1 sup> to 0.9999 ohms accuracy class 1,0
from 5 x 10 -3 sup > to 0.0999 ohms accuracy class 15.0
from 100000 to 999900 Ohm; accuracy class 5,0 td> tr>Resistance shoulder decade older stage of comparison bridge P333 td> 1000 Ohm td> tr> resistance shoulders relationship P333 td> for at least 1 ohm td> tr> A variation of the initial resistance of the comparative shoulder store caused by the change in contact resistance and contact switching devices P333 td> < td> no more than 0.003 ohm td> tr> Initial resistance comparative shoulder store, ie. resistance when installing all the decades of the switches on the zero indication P333 td> is not more than 0.02 ohms td> tr> The insulation between insulated from the housing conductive circuits and the body withstands during 1 min. testing voltage P333 td> 500 V, 50 Hz td> tr> Toggle switches bridge can withstand without any defects P333 td> 50 000 moves td> tr> ambient temperature P333 td> +10 ... + 35 ° C td> tr> Overall sizes P333 td> 300 x 230 x 150 mm td> tr> Weight P333 td> no more than 5 kg td> tr> table> P333 operating Conditions:
ambient air temperature, ° C:. +10 ... + 35
relative humidity.%: 80 p>weight: 5 kg .
Dimensions:. 300h230h150 mm p> Replaces: IIMTerms and Conditions Shipping and payment Warranties & Returns Contacts Documentation for download of the device not available