"CELS" - center of measuring systems. ph.: (095)191-68-69, (098)191-68-69 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

Production / Non-destructive testing equipment / Dosimeters / monitor radiation MPS-01 "Kordon-MN"

monitor radiation MPS-01 "Kordon-MN"

Specify the price
Availability: under the order   Condition: new




IPU-radiative Monitors 01 "Cordon-MH" (hereinafter the monitor) is designed for continuous measurement of the radiation level of the monitored object, comparing the measured values ​​with the background radiation level, signaling the exceeding of the measured values ​​over a background. Registration and analysis of ionizing radiation in the monitor is carried out by comparing the emission from the controlled object from the background radiation levels at the site of the monitor locations without direct measurement of the numerical values ​​which either normalized emission characteristics.

The monitor is used at security checkpoints for various purposes : road, rail and pedestrian border control, PPC nuclear power plants, enterprises of atomic-industrial complex, the metallurgical enterprises, the enterprises for extraction, processing and storage of radioactive and nuclear materials processing facilities and storage of radioactive waste, PPC government agencies, banks, offices etc.

Detection monitor radioactive substances and nuclear materials is given in the form of signals showing that the controlled object radiation exceeds a selected threshold limits with respect to the external background radiation.

Monitor represents It is a stationary device, consisting of a structurally complete blocks:

- radiation detection panel ol with blocks gamma BDPS;

- PRI controllers;

- sensors KBKH object;

- OL radiation panel with neutron detecting units BDPN;

- signaling block BIC;

- BNN supply unit;

-. industrial panel computer PPC

radiation panel gamma completed one of the two detection units BDPS depending on delivery options. Each detection block includes an organic scintillation detector sensitive volume which is 7000 cm3 or 12500 cm3. To reduce the influence of natural gamma background detector with three sides except the front, closed lead shield.

The radiation panels neutron radiation as two neutron detectors are used 3He proportional counters 800 cm3 in volume. The counters are placed in the moderator made of a polyethylene.

An industrial panel computer monitor at the same time can be connected to up to four radiation monitoring portals. Each portal may contain from 2 to 8 radiation panels. Panel computer has the following default ports and interfaces for connecting peripheral equipment:

- two serial RS-232 port;

- parallel port PS / 2;

- USB port;

- Port Mic-in / Line-out;

-. Ethernet 10/100 Base-T

Power panel computer monitor is carried out either by an AC voltage of 135 ... 242 V or DC voltage + 24VDC power supply BNN. In the case of the disappearance of the mains power supply, the monitor automatically switches to power supply from BNN built-in power supply and battery for at least 8 hours performs all its functions. The battery pack is automatically charged when the mains power supply. In an accident the AC power (exceeding the upper voltage threshold) in the BNN unit automatically triggered protection. Restart the power supply is possible only after the elimination of the causes of the accident by briefly pressing the button "Reset relay».

The signaling unit CIC for audible and visual alarm when the monitor alarm. Mounted on the top panel of the radiation of one of the measuring column. The sound pressure level when an alarm is not less than 80 dB at a distance of 1 m.

CBC object sensors designed to detect the presence of an object in the monitored area by crossing the last infrared ray. Are arranged in pairs (receiver - transmitter) in opposite radiation panels measuring columns

At the request of the consumer with the monitor MPS-01 "Kordon-MN" can be turned on a digital video surveillance system "Patriot" ..

radiation Monitors MPS-01 "Kordon-MN" produced in accordance with the specifications TU U 33.2-19310157-017: 2006. Specifications have passed sanitary-hygienic examination and agreed Dnipropetrovsk regional SES (conclusion of the state sanitary-hygienic examination number 9833 of 06.03.2006g.).

Specifications

thresholds of detection the active source of gamma radiation in the control w / d transportation

Activity gamma source, Still, kBq

americium-241
( 241 Am)

barium-133
( 133 Ba )

cesium-137
( 137 Cs)

cobalt-60
( 60 Co) < / td>

thorium-228
( 228 Th)

60000

350 < td>

600

340

< span> 200

The width of the passage between the radiant panels 6.2 m, height 4 m above the railroad tracks, the traffic rate is not more than 25 ± 2 km / h. The probability of detecting the above values ​​of at least 0.5 with certainty 95%.

Detection Thresholds active source of gamma radiation in the control vehicle

Activity gamma source, however, kBq

americium-241
( 241 Am)

barium-133
( 133 Ba) < / td>

cesium-137
( 137 Cs)

cobalt-60
( 60 Co)

< span> thorium-228
( 228 Th)

2000

95

170 < / span>

90

60

passage width & nbsp; between panels radiation 6 m , height 3.5 m from the road level, traffic speed not more than 10 ± 2 km / h . The probability of detecting the above values ​​of at least 0.5 with certainty 95%.

Detection Thresholds active source of gamma radiation when monitoring pedestrians from one side

Activity gamma source, however, kBq

americium-241
( 241 Am) < / span>

barium-133
( 133 Ba)

cesium-137
( 137 Cs)

cobalt-60
( 60 Co)

< p> thorium-228
( 228 Th)

1700

70

120

65

45

Width sided control zone 1.5 m , height 2 m from uro vnya floor speed of the object & nbsp; less than 5 ± 1 km / h . The probability of detecting the above values ​​of at least 0.5 with certainty 95%.

Detection Thresholds active source of gamma radiation under the control of pedestrians on both sides

The activity of the gamma source, however, kBq

americium-241
( 241 Am) < / span>

barium-133
( 133 Ba)

cesium-137
( 137 Cs)

cobalt-60
( 60 Co)

< p> thorium-228
( 228 Th)

160

6

11

6

4

Width control zone 0.7 m , height 2 m from floor level, speed etc. The motion of the object is not more than 5 ± 1 km / h . The probability of detecting the above values ​​of at least 0.5 with certainty 95%.

Thresholds neutron flux detection at the control rail transport

The neutron flux neutron sources, neutron / s

californium-252
( 252 Cf)

plutonium-beryllium
(Pu-α-Be)

25,000

100000

passage width & nbsp; between panels radiation 6.2 m , height 4m the level of railway track, traffic speed not more than 25 ± 2 km / h. The values ​​given for the probability of false alarms at most 0,001

Thresholds neutron flux detection in the control of road transport < br>

neutron flux neutron radiation source, neutron / s

californium-252
( 252 Cf) < / p>

plutonium-beryllium
(Pu-α-Be)

11000

45000 < / tr>

passage width & nbsp; between panels radiation 6 m , height 3.5 m from the road level, traffic speed not more than 10 ± 2 km / h. values ​​are for the probability of false alarms at most 0,001

thresholds neutron flux detection when monitoring pedestrians from one side
< / strong>

neutrons a neutron radiation source flux, neutron / s

californium-252
( 252 Cf)

plutonium-beryllium
(Pu-α-Be) < tr>

4500

18000

Width sided zone control 1.5 m , height 2 m from the road level, speed of the object is not more than 5 ± < / span> 1 km / h. The values ​​given for the probability of false alarms at most 0,001

Thresholds neutron flux detection when monitoring pedestrians on both sides

a source of neutron radiation neutron flux neutron / s < / p>

californium-252
( 252 Cf)

plutonium-beryllium
(Pu-α-Be)

400

1600

zone width control 0.7 m , height 2 m from the floor, the velocity of the object is not 5 ± 1 km / h. The values ​​given for the probability of false alarms at most 0,001

The sensitivity of the gamma radiation detection unit BDPS to radiation radionuclide located in a fixed position on the door of each radiant panel is not less than, (counts / s) / kBq:
- 5 for radionuclide 241 Am;
- 70 for radionuclide 133 Ba;
- 60 for radionuclide 137 Cs;
< span> - 110 radionuclide 60 Co;
- 70 for radionuclide 228 Th
. in this expanded uncertainty sensitivity detecting unit does not exceed ± 30%.

sensitivity neutron radiation detection unit BDPN a neutron radiation source 252 Cf (or Pu- α-Be), located in a fixed position on the door of each radiation panel is not less than 0,013 counts / neutron. Extended sensitivity uncertainty detecting unit does not exceed ± 50%.

Time of operating the monitor mode is not more than 30 min.

Time continuous operation of monitors running on AC power for at least 24 hours a day, with an autonomous power supply from the battery -. at least 8 hours

The average time to failure of the monitor for at least 10,000 hours ..

the average lifespan of the monitor for at least 10 years with the replacement of individual (leading to non-conformity to the threshold of detection and false alarm rate as a criterion of failure is accepted violation of the monitor) modules and components, worn out.

operating Conditions

ambient temperature, ° C
- for detection units
- measuring unit and the power supply

-30 to +50
+5 to +50
relative humidity (at a temperature of + 35 ° C) no more than,%
- for the detection of
blocks - measurement and power supply unit

95 < br> 80
Atmospheric pressure, kPa. from 84 to 106 7

Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts

Documentation for download of the device not available