"CELS" - center of measuring systems. ph.: (095)191-68-69, (098)191-68-69 e-mail: zakaz@cels.com.ua Working hours: 9-00 - 18-00

Production / Non-destructive testing equipment / Dosimeters / Analyzers multichannel parallel account AMP-12 "Pulse-1A"

Analyzers multichannel parallel account AMP-12 "Pulse-1A"

Specify the price
Availability: under the order   Condition: new




The analyzer multi-channel parallel counting AMP-12 "Puls 1A" (the analyzer) is the main structural element of the automated radiation monitoring system (ARMS) nuclear power plant and is intended to create a new system or upgrading existing AKRB-03, 06, 08 and their analogues which are constructed by three-level scheme: the first (lower) level - units and the detection device, the second (low) uroven- storage device and information processing, and the third (upper) level - a set of technical means integrating all storage device and information processing, and performing control operation of the system as a whole.

analyzer for the simultaneous reception of several channels of pulse signals from the detection units and devices (DB and CA) of ionizing radiation in the form of sequences of statistically distributed pulses and pulse counting rate measurements; simultaneous reception of several channels of analog DC signals and voltages from the sensors with standardized output signals and the conversion of a physical quantity for each measurement channel

-. The analyzer used in the measurement information systems, radiation monitoring for normal operating conditions (AI IBS-H) NPP

-. Analyzer is a means of measuring equipment according to GOST 27452-87 and refers to the AI-IBS H nuclear technical means

-. The analyzer according NP 306.5.02 /3.035-2000 relates to the technical automation means (TCA) information systems in normal operation.

-By influence on safety analyzer NPP relates to a class of normal operation and is classified as according to 3H NP 306.1.02 / 1.034-2000.

Specifications

speed measurement range of pulse counting, with -1 0.01 × 10 6 4
frequency range register input pulses Hz 1 × 10 -2 to 6 × 10 4
amplitude pulses in 3 to 12
duration pulses microseconds 0.2 to 2.5 (at least 50% of the pulse amplitude)
pulse polarity positive
Number of channels for receiving pulse signals less than 60
measurement range DC current mA from 0.05 to 20
measurement range DC voltage, 0.1 to 10
number of input signals DC and the voltage less than 60
Instability of readings, % not more than 0,5
continuous operation time, hours a day 24
Operation mode setup time, min to 2
measuring time with:
- at the rate of pulse counting measurements;
- the measurement of DC

from 1 to 10000
to 2 < / span>
power consumption in view of power consumption connected to the analyzer unit and the detecting devices, VA no more than 950

embodiments

The analyzer has a block - of modular design and is available in three versions:
- a cabinet for mounted on a wall, in which one set is located anali jam;
- in cabinet for mounting on the wall, which is located no more than two sets of the analyzer;
- in cabinet for mounting on the floor, which houses up to three sets of blocks and analyzer units .

Terms and Conditions   Shipping and payment   Warranties & Returns   Contacts

Documentation for download of the device not available

To order, fill out the form


cels.com.ua

Callback order form

cels.com.ua